50100
4. CONNECTING TO GAS
Fig.3
This appliance is designed to be installed with an appliance
flexible connection only. Supply piping should not be less
that R3/8. Connection is made to the Rc 1 (1" B.S.P.)
female threaded entry pipe located just below the hotplate
level on the rear left hand side of NOTE:the appliance.
ONLY LIQUID SEALANTS TO BE USED WHEN INLET
GAS PIPE IS FITTED TO SHUT OFF VALVE I.E.: DO
NOT USE P.T.F.E. SEALANT TAPE. Check for gas
soundness after connecting to the gas supply.
The gas bayonet connector must be fitted in the shaded
area indicated in Fig.3. Take into account that it must be850
possible to pull the appliance forward sufficiently. The hose0
must not get caught on the stability bracket.70
IMPORTANT: FLEXIBLE TUBING USED MUST COMPLY
WITH BS. 669 CURRENT EDITION.
L.P.G. FLEXIBLE CONNECTIONS MUST BE OF A TYPE50
4
SUITABLE FOR L.P.G. AND CAPABLE OF OPERATION250
UP TO 50 mbar AND TO CARRY A RED STRIPE, BAND
OR LABEL.
375
All dimensions in mm
5. CONNECTION TO THE ELECTRICITY SUPPLY
WARNING: THIS APPLIANCE MUST BE EARTHED. DO NOT EARTH THIS APPLIANCE TO THE GAS
SUPPLY PIPING.
This appliance must be connected to 220V-240V A.C. 50Hz
supply. It is supplied with 2 metres of 5 amp 3 core cable
incorporating a moulded 13 amp plug, fitted with a 3 amp fuse,
which can be plugged directly into the nearest suitable socket. If
this is not long enough, the supply cable can be replaced totally by
a longer cable at least 0.75mm2 nominal cross sectional area
(24/0.2mm).
IF THE MOULDED PLUG IS CUT FROM THE CABLE FOR ANY
REASON, IT MUST BE DESTROYED OR DISPOSED OF
SAFELY, AS THE PROTRUDING WIRES WILL BE AN
ELECTRIC SHOCK HAZARD.
If any other type of plug is used it should incorporate a 3 amp fuseFig.4
in either the plug or adapter or at the distribution board.
If the cable has to be threaded through small apertures in cabinets etc., it may be disconnected from the
appliance, then re-connected to as shown in Fig.4.
DO NOT EXTEND THE CABLE USING PLASTIC OR CERAMIC CONNECTION TERMINAL BLOCKS
AND/OR INSULATION TAPE.
ALL EXTERNAL WIRING BETWEEN THE APPLIANCE AND THE ELECTRICAL SUPPLY SHALL
COMPLY WITH I.E.E. WIRING REGULATIONS.
40 |